Parameter
|
Value
|
Frequency band
|
3.400 to 4.200 GHz
|
Input waveguide flange
|
CPR-229G
|
Input V.S.W.R.
|
3:1 max
|
Noise temp. (Ta=+25 C)
|
35 K typ. to 45 K max.
|
Output frequency
|
0.95 to 1.75 GHz
|
Conversion gain
|
60 dB min @ +25C
66 dB max.
|
Conversion gain variation (Ta=+25C)
|
2 dB max. in any 50 MHz segment over frequency band
|
Conversion gain flatness (Ta: +25 C)
|
8.0 dB max. at 800 MHz BW
|
Local oscillator frequency stability (Ta= -40 to +60 C)
|
5.15 GHz nom.
|
Image rejection
|
60 dB min.
|
Output V.S.W.R.
|
2.5:1 max.
|
Power requirement
|
+13.5 to +24 VDC
|
Current drain
|
400 mA max.
|
Phase noise (SSB)
|
-70
dBc/Hz typ. -65 dBc/Hz max@100
Hz
-80
dBc/Hz typ. -75 dBc/Hz max@1
KHz
-85
dBc/Hz max@10 KHz
-90
dBc/Hz max@100 KHz
-105
dBc/Hz max@1 MHz
|
|
|
Parameter
|
Value
|
Operating temperature range
|
-40 to +60 C
|
Storage temperature
|
-40 to +80 C
|
Humidity
|
100 %Rh (max)
|
Vibration
|
G=5 (f=50±2Hz, t=5 min, Direction; X,Y,Z)
|
Shock
|
G=15 (Direction; X,Y,Z)
|
RF input power
|
-10 dBm (@ CW)
+10 dBm (@ pulse)
|
Supply voltage
|
+28 VDC
|
|