Parameter
|
Value
|
Output interface
|
CPR 137-G (Grooved) with
flange
|
Output power @ P1 dB
|
+33 dBm minimum over temperature
|
Conversion gain
|
58 dB nom.
|
Phase noise (SSB)
|
-60 dBc/Hz max. @ 100 Hz
-70 dBc/Hz max. @ 1 KHz
-80 dBc/Hz max. @ 10 KHz
-90 dBc/Hz max. @ 100 KHz
|
Input interface
|
N-type, female (50 ohm) [NJT5667 / NJT5668]
F-type, female (75 ohm) [NJT5667F / NJT5668F]
|
Required external reference Signal
|
frequency: 10 MHz
input power: -5 to +5 dBm
Phase
noise:
-135 dBc/Hz @ 100 Hz
-140 dBc/Hz @ 1 KHz
-143 dBc/Hz @ 10 KHz
-143 dBc/Hz @100 KHz
|
|
|
Parameter
|
Value
|
Mute
|
Shut off the HPA in
case of LO unlocked
|
Input / output V.S.W.R.
|
2.0:1 max. @ input
2.0:1 max. @ output
|
Power requirement
|
+15 to +30 VDC
|
Power consumption
|
37.5 W max.
|
Operating temperature
|
-40 to +55 degrees C
|
Storage temperature
|
-40 to +75 degrees C
|
Size & Weight
|
190.6 mm (L) x 167.1 mm (W) x 59 mm (H), 2.54 kg max.
[7.50” (L) x 6.58” (W) x 2.32” (H)] [5.6 lbs]
|
|